SERVICE
TIP
Why are
the air lines and control valves for the aeration pads full of cement?
Cause
- Aeration pads
damaged by high pressure allowing cement to migrate into airlines
- Filter / regulator
not operating properly
- Pressure set too
high
Test
- Check ALL aeration
pads for damage
Solution
- Replace ALL aeration
pads (mandatory)
- Clean cement from
all airlines or replace
- Replace damaged air
control valve
- Replace filter /
regulator if damaged
- Set pressure on
filter / regulator no higher than 7 psi on any aeration system
Contact our 24-hour
parts service by phone (800) 330-5590 or (210) 333-1111, or fax (210)
333-1508. All
calls received after hours will be forwarded to the pager or mobile phone
of the representative in your area. E-mail us anytime at sales@besser.com.
Posted 6 November 2000
|